Category: Helium, SF6 Gas Recovery Plant > Helium Recovery Plant >
Page : | 1 |

KG10V-2.2OL-P



Model KG10V-2.2OL-P
First pressure recovery Under 0.5MPa
Exit pressure recovery ・2.66kPa abs
Storage tank capacity 80 liters (about stockpile 5kg)
Recovery time 15 minutes (0.5MPa → 2.66kPa・abs) ※ 1 
※ 1 time = 0.13m 3 capacity recovery equipment
Power Or AC200V × 50/60Hz × 3Φ 
AC220V × 60Hz × 3Φ
Installation conditions Indoor mobile
Options Pirani vacuum gauge, for additional storage tanks, SF6 gas density meter, dew point
Model KG10V-2.2OL-P
First pressure recovery Under 0.5MPa
Exit pressure recovery ・2.66kPa abs
Storage tank capacity 80 liters (about stockpile 5kg)
Recovery time 15 minutes (0.5MPa → 2.66kPa・abs) ※ 1 
※ 1 time = 0.13m 3 capacity recovery equipment
Power Or AC200V × 50/60Hz × 3Φ 
AC220V × 60Hz × 3Φ
Installation conditions Indoor mobile
Options Pirani vacuum gauge, for additional storage tanks, SF6 gas density meter, dew pointModel KG10V-2.2OL-PFirst pressure recovery Under 0.5MPaExit pressure recovery ・2.66kPa absStorage tank capacity 80 liters (about stockpile 5kg)Recovery time 15 minutes (0.5MPa → 2.66kPa・abs) ※ 1 ※ 1 time = 0.13m 3 capacity recovery equipmentPower Or AC200V × 50/60Hz × 3Φ AC220V × 60Hz × 3ΦInstallation conditions Indoor mobileOptions Pirani vacuum gauge, for additional storage tanks, SF6 gas density meter, dew point
 

KL40V-3.7OL-RSP



Model KL40V-3.7OL-RSP
First pressure recovery Under 0.6MPa
Exit pressure recovery ・2.66kPa abs
Storage tank capacity 47 liters × 2 (storage capacity of about 90kg)
Recovery time 70 minutes (0.6MPa → 2.66kPa・abs) ※ 1 
※ 1 time = 1.0m 3 capacity recovery equipment
Power Or AC200V × 50/60Hz × 3Φ 
AC220V × 60Hz × 3Φ
Installation conditions Indoor mobile
Options SF6 gas density meter, dew point
 

KL40V-19-S



Model KL40V-19-S
First pressure recovery Under 0.6MPa
Exit pressure recovery ・2.66kPa abs
Storage tank capacity 1,000 liters (about storage capacity 1000kg)
Recovery time 30 minutes (0.6MPa → 2.66kPa・abs) ※ 1 
※ 1 time = 1.0m 3 capacity recovery equipment
Power AC200V × 50/60Hz × 3Φ or AC220V × 60Hz × 3Φ
Installation conditions Indoor mobile
Options SF6 gas density meter, dew point
 

KL50V-5.5OL-P



Model KL50V-5.5OL-P
First pressure recovery 0.7MPa
Exit pressure recovery 5kPa · abs (recovery rate 99%)
Storage tank capacity 300 liters (about stockpile 300kg)
Recovery time About 73 min (0.7Mpa → 5kPa · abs) ※ 1 
※ 1 time = 1.0m 3 capacity recovery equipment
Maximum discharge power Under 4.65MPa
Vacuum pressure reached 133Pa · abs below
Power Or AC200V × 50/60Hz × 3Φ 
AC200V × 60Hz × 3Φ
Installation conditions Indoor mobile
Options Additional storage tanks, 
SF6 gas density meter, dew point
 
Page : | 1 |